Download
General Usage:
- Scripts can be added to the toolbar now
- Change company name on the registration dialog
- Fix problem with unsorted measurement object list after the name of a measurement function has been changed
- Fix problem for command "change dimension with interpolation" in case of a invalid map or curve
- Fix problem in the measurement list if letters are entered
- Saving the default settings does work for graphic windows again
- Maximizing a display window does maximize the selected window and not a second minimized window
- Closing the properties dialog of a database object in read-only mode with "OK" will not set modified flag
- Correction in copy and save a string value to PAR file
- Fix read problem of settings for user defined filters
- Functions with virtual signals assigned to input parameters are executed regardless of the order in the measurement list
- Fix problem with the measurement cursor in empty text windows if 'Strg' or 'Shift' is pressed
- Fix problem with non modal error message box during loading a configuration, if the symbol explorer is open
- Curve without axis can be inserted into an existing calibration window
- Addon Tool menu entries can be defined in the registry
- Fix problem with location of the context menu for multiple monitor systems
- Fix problem with script function LoadConfiguration()
- Fix problem for the ATF-Converter when converting an mdf-file with the script function ConvertFile()
- Fix problem with duplicated global variables in the function editor
- Fix problem if the info dialog is open and the permanent offline mode is changed because a inserted/removed license
- Measuring mode "On Start" does save always one value in case of a triggered measurement
- Support trigger condition on same named CAN signals which are defined in multiple messages
- Display of physical value with measurement cursor is not restricted any more to min/max physical values defined in database.
- Added possibility to suppress dialog "Adjustment of calibration ram" by executing default action
- Optimization of the logging converter for CANcaseXL log measurement files
- Do not show a trigger line in graphic windows after a measurement without a trigger
- Fix problems in case of logging J1939 messages with more then 8 data bytes into a BLF
- "Remark" can be saved for an "ASCII String" variable
- Calibration windows are updated now if a HEX parameter file is loaded and the ECU is offline
- Fix problem in the Measurement File Manager when closing dialog for an invalid virtual signal
- Fix some memory leaks caused by calling function of function Dll's with string arguments
- Function sizeof() does work for MDF file signals now which are not already created
- The datatype unsigned long does work in the function editor now
- Fix some memory Leaks during compiling scripts or functions
- Fix problem with invalid configured dependent parameters
- Fix problem when closing a configuration containing a array measurement object with a not complete measured axis
- Delete temporary files of imported CANalyzer logging files if the file device is permanent loaded
Map Reader:
- COFF reader outputs supports values if bit fields which cross byte borders
- Fix problem with invalid addreses read from elf file generated by MW EABI PPC C-Compiler
- Fix problem with ASCII string variables linked to an entry of an ELF map file
Driver:
- VCANTCP: Fixed data corruption problem
- Analog driver (IOcab): Prevented resetting values in calibration window upon refresh
- GPS driver: Corrected values of position/dilution, added additional satellite information
- NI-DAQ driver: Fixed problems with PCI-MIO-16XE-50
- Fix problem with CNP_CREATE_INI driver entries in an a2l-file
- A variant criterion can not be assigned to a database group that contains the associated selector
- Custom Audi K-line driver : Read access to calibration object led to suspend/resume of free running mode even if the values are cached.
- Corrected format of blf log file created by CAN device
- Support of Transport protocoll in case of multiple CAN devices using J1939 CANdb's
- Improved import of LIN ldf-files
- Fixed problems in CANdito when creating device using fibex-file
MDF:
- Display error message during MDF signal selection because a signal comment with more then 255 characters.
- Save time range of a multmedia signal into a new MDF file does not modify the avi file link in the base multimedia signal anymore.
- Support Integer time stamps with more then 32 Bit in MDF measurement files
- Fix problem with channel counter of MDF files if arrays are saved in one channel group or block measurement mode is used
- Fix problem during configuration of a virtual MDF signal if a not allowed parameter is selected which is already assigned
- Fix problem at reading or writing an Integer signal with Motorola Byte order in an MDF file and a bit offset
- Support J1939 BAM at converting BLF files into MDF files
Diagnostics:
- Fixed wrong "no interpretation possible" warnings for empty strings in the trace of the diagnostic console.
- Changed text for physical ./. functional addressing from "Addressing Scheme" to "Addressing Mode"
- If a response parameter value is invalid now additionally an according message appears (along with the raw hex value output)
- CANape could crash when a diagnostics device was changed from physical to functional addressing
- The message box of the diagnostic console that warns in case of invalid parameter values was adapted for huge parameter lists
- Fixed bug that caused a crash after changing the communication interface of a diagnostic driver
- Fixed some wording problems in string resources of the diagnostic driver dialog
- Now it's possible to override the used fault memory requests also for the K-Line driver
- Optimized bus load in diagnostics driver during measurement

Contact