Download
With Service Pack 1, the following changes become effective:
General:
- Partial loading of windows displayed on multiple pages works correct now
- Visibility of the undocked symbol explorer is assured
- Fixed problem with Macros for Text To Speech
- Fixed Problem with curve windows and more than 10 curves
- Fixed partial loading of windows which were displayed on multiple pages
- GUI harmonisation for CANditoFlash
Measurement:
- Saving a measurement label list is possible even if no device is selected
- Curves with one column and multiple rows are now always handled like array signals
- The logging file of the write window is completely write when measurement stops
Calibration:
- Indirect modified parameters that are in the measurment list, are not updated until their new value is downloaded to the ECU
- KWP2000 on K-line: KW_Standard.dll now supports parameter calibration while measurement is running
Flash Programming:
- Use seed&key dll when flashing via CCPflash.exe
- Possibility to reduce STmin to speedup flashing
- CCP/XCP: Unlock required protocol resources for flashing
Database Editor:
- Sort order of the database explorer lists are saved individualy for each object type
Functions and Scripts:
- Path of a script added to the Extras menu can be relative now
- Measurement file signals can be directly accessed by functions to create virtual MDF signals
- Usability of th function browser "Intellisense" improved
Communication Protocols:
- Handle french keywords for memory segments in ASAP2 file
- Full support of J1939 for CANalyzer/CANoe ASC logging files
- Support of CAN DBC databases with multiple multiplexer signals
- Support of all LIN message types of CANalyzer/CANoe BLF logging files
- Fixed issue when importing A2L database which resulted in corrupt flash offsets
Data Management:
- Improved handling of variant codded parameters of the current device (C&P, save as...)
- Improvements in reading DCM and CVX file which contains parameters using a symbol conversion table
- Improvement in loading variant coded maps with standard axis
- Improvement in handling parameters with overlapping addresses in the save action
Offline analysis measurement files:
- Improved signal selection from measurement files
- A start time can be specified for importing of ASCII measurement files.
- A time unit (factor) can be specified for importing of ASCII measurement files.
- Command line option -M opens a measurement file without a signal selection dialog
- The comment in created Diadem export files is checked for unsupported characters.
- The first Application Text Object in an CANalyzer/CANoe BLF logging file is used as comment for the MDF file.
- Measurement files loaded inside the measurement file manager are loaded permanently.
Diagnostic:
- Fixed problem in CANape scripting regarding diagnostic response handles in case of mixed physical/functional addressing usage
- Fixed problem with CANape scripting command DiagSendRequest() in case of raw messages if no diagnostic database is used
- Performance improvement building the service tree of the diagnostic console window
- Fixed problems regarding bit field handling of CANdela service parameters
Map Reader:
- ELF mapfile reader supports bit structures correct now.